+44 (0) 151 909 2333

High Accuracy Current Sensors

SATEC HACS


SATEC HACS - High Accuracy Current Censors

SATEC HACS concept CTs are designed to bring accuracy in energy metering and the safety of your facility to a new level

Superior accuracy

  • Solid Core: 0.1%
  • Split Core: 0.5%

Safety Switch

  • All HACS have a built-in automatic protection circuit for maximum safety
  • No shorting bars needed

Remote installation

  • All HACS are supplied with 8ft / 2.5m cable
  • Maximum cable length: 650ft / 200m
  • Minimal cost for retrofit installation

SATEC Devices with HACS-model availability

  • EM13x-HACS /RS5
  • PM13x-HACS/RS5
  • BFM136 (only HACS compatible)
  • BFM II (only HACS compatible)
  • PM17x-HACS /RS5
  • PM180 (several models, consult manual)
  • PRO PM335-HACS/RS5
  • PRO EM235-HACS/RS5

Description

With over 100,000 units installed in different commercial, industrial, residential and utility applications, SATEC HACS CTs are your go-to for a safe facility, easy installation and high accuracy, which is what metering is all about.

HACS Safety Feature

SATEC HACS feature an electronic switch which provides an automatic protection circuit for maximum safety.

This prevents the fires and explosions, discussed above, which unfortunately occasionally occur when standard CTs are improperly disconnected.

Maximum Accuracy

Standard energy meters feature current inputs typically rated at 5A or 1A, making the meter reliant on an external CT to step-down standard distributed electrical currents.

These two stepdown transformations (external + internal) result in a combined error which is the product of an aggregation of factors:

  • Meter error: affected by amplifiers, A/D converters, passive components and noise resulting from circuit design
  • Meter's built-in CT error
  • External CT error
  • CT phase shift: an additional parameter affecting accuracy, varying, even within the same product of any manufacturer, from one batch to the another

SATEC designs its meters in compliance with a minimal accuracy standard of Class 0.5S. Many SATEC products feature a yet more advanced accuracy standard of Class 0.2S. To guarantee overall system accuracy, featuring a minimal metering error, SATEC designed the HACS CTs.

HACS feed their secondary current outputs directly into corresponding designated SATEC meter models which feature low current inputs (mA).

Maximum Convenience

  • Benefit from the protection circuit with any disconnection initiated - no shorting blocks needed!
  • The extremely low burden which characterizes the HACS allows the user to run wiring from the meter to loads positioned up to 200 meters away from the SATEC power-meter, without any compromise whatsoever on accuracy, employing wiring as thin as 16 AWG.

Standard Compliance

  • IEC 61869-1 Instrument transformers - Part 1: General requirements
  • IEC 61869-2 Instrument transformers - Part 2: Additional requirements for current transformers

Models

The selection of HACS varies according to your choice of instruments

  • CS05S

    SATEC HACS CS05S
    • Rating: 10A
    • Split core
    • Accuracy: 0.5%
    • Window: Ø 16mm / 0.63″
  • CS1

    SATEC HACS CS1
    • Rating: 100A
    • Solid core
    • Accuracy: 0.1%
    • Window: Ø 12mm / 0.47″
  • CS1L

    SATEC HACS CS1L
    • Rating: 100A
    • Solid core
    • Accuracy: 0.1%
    • Window: Ø 23mm / 0.9″
  • CS1S

    SATEC HACS CS1S
    • Rating: 100A
    • Split core
    • Accuracy: 0.5%
    • Window: Ø 16mm / 0.63″
  • CS1H

    SATEC HACS CS1S
    • Rating: 100A
    • Split core
    • Accuracy: 0.1 / 0.2%
    • Window: Ø 13mm / 0.5″
  • CS2

    SATEC HACS CS2
    • Rating: 200A
    • Solid core
    • Accuracy: 0.1%
    • Window: Ø 23mm / 0.9″
  • CS2S

    SATEC HACS CS2S
    • Rating: 200A
    • Split core
    • Accuracy: 0.5%
    • Window: 25×23mm / 0.96×0.9″
  • CS2SL

    SATEC HACS CS2SL
    • Rating: 200A
    • Split core
    • Accuracy: 0.5%
    • Window: 43×33mm / 1.69×1.3″
  • CS250S

    SATEC HACS CS250S
    • Rating: 250A
    • Split core
    • Accuracy: 0.5%
    • Window: 24×25mm / 0.94×0.98″
  • CS4

    SATEC HACS CS4
    • Rating: 400A
    • Solid core
    • Accuracy: 0.1%
    • Window: Ø 26mm / 1.02″
  • CS4S

    SATEC HACS CS4S
    • Rating: 400A
    • Split core
    • Accuracy: 0.5%
    • Window: 43×33mm / 1.69×1.3″
  • CS4L

    SATEC HACS CS4L
    • Rating: 400A
    • Solid core
    • Accuracy: 0.1%
    • Window: Ø 45mm / 1.77″
  • CS8

    SATEC HACS CS8
    • Rating: 800A
    • Solid core
    • Accuracy: 0.1%
    • Window: Ø 60mm / 2.36″
  • CS8S

    SATEC HACS CS8S
    • Rating: 800A
    • Split core
    • Accuracy: 0.5%
    • Window: 80×50mm / 3.1×1.9″
  • CS12S

    SATEC HACS CS12S
    • Rating: 1200A
    • Split core
    • Accuracy: 0.5%
    • Window: 120×80mm / 4.7×3.15″
  • CS20A

    SATEC HACS CS200A
    • Rating: 2000A
    • Split core
    • Accuracy: 0.5%
    • Window: 160×80mm / 6.3×3.15″
  • CS30A

    SATEC HACS CS300A
    • Rating: 3000A
    • Split core
    • Accuracy: 0.5%
    • Window: 160×80mm / 6.3×3.15″

Installation Recommendations

All HACS include a built-in automatic protection circuit for maximum safety, eliminating the need to use shorting bars.

  • All HACS are supplied with 8ft / 2.5m cable.
  • Maximum cable length: 650ft / 200m.
  • Recommended wire gauge: ≥1.5 mm2

It is recommended to use a shielded twisted extension cable to connect between the HACS and the SATEC meter. The cable shield must be connected to protective ground.

It is recommended to locate HACS cable in separate cable conduit and at least 1m (3ft) away from High Voltage circuits, and / or other high power magnetic fields.

HACS Configuration In Metering Unit

SATEC HACS Configuration in PAS

When configuring the meter, make sure to set the value of the HACS CT primary current, either via the front panel of the unit or via the PAS software.

Set the “Primary current” value in the unit configuration as HALF the value stated above in sheet as “RATED CURRENT”, per each HACS CT model. e.g., for the CS4S model, rated at 400A, feed “200” as primary current.

RS5 Primary Current: the RS5 model stands as an exception, in which the value entered is “5”.

Configuring the PM180 analyzer: rated values vary when configuring the product. Please consult the PM180 manual.

Downloads