Features
- Full IEC 60255-118-1:2018 / IEEE C37.118.1 compliance for both:
- M-Class
- P-Class
- Dual Protocol
- IEC 61850-9-2
- IEEE C37.118.2
- Versatile micro-second resolution time-sync:
- PTP
- IRIG-B
- Up to 240 frames/sec
- Super-compact design
- Expected Steady State Total Vector Error (TVE) at nominal frequency < 0.05%
Description
A Phasor Measurement Unit (PMU) is a sophisticated sensor that measures synchronized phasors (magnitude and phase angle) of voltage and current on the power grid.
Key features of PMUs include:
- High sampling rates for capturing rapid changes
- Precise GPS time-stamping for synchronized measurements
- Real-time data transmission for immediate analysis
PMUs offer significant benefits for power system management, including:
- Wide-Area Monitoring (WAMS): Providing a real-time overview of the interconnected grid.
- Improved Grid Stability: Detecting and mitigating oscillations that can threaten system integrity.
- Faster Fault Detection and Location: Enabling quicker power restoration after outages.
- Enhanced Situational Awareness: Giving operators the information needed to make proactive and informed decisions.
Applications
PMU PRO - Phasor Measurement Unit
- IEEE C37.118.1-2011, IEEE C37.118.1a-2014 and IEC/IEEE 60255-118-1:2018 P-Class and M-class performance compliance
- Clock synchronization to a UTC time reference using an IRIG-B timecode source or an IEEE 1588 PTPv2 master clock source
- Streaming of phasor data over Ethernet using the IEC 61850-9-2 multicast sampled value (SV) service with IEEE C37.118.2 compliant mapping of synchrophasor data upon IEC 61850-9-2 and IEC 61850-90-5 guidelines
- Expected steady-state total vector error (TVE) at nominal frequency: < 0.05%
- IEEE C37.118.1
- Compliant 3-phase voltage, current, positive and negative sequence phasor measurements synchronized to a common UTC time reference
- Synchronous frequency and Rate of Change of Frequency (ROCOF) measurements
- IEEE C37.118.2
- Commanded client-server UDP and TCP data transmission and spontaneous UDP data transmission over IP protocol
- Streaming rates up to 200 frames/s @ 50Hz and up to 240 frames/s @ 60Hz
- Synchrophasor data frames transmit a time stamped set of measurements including phasor estimates, frequency deviation from the nominal power, line frequency or actual frequency, rate of change of frequency.
- Data frame can be expanded to contain analog data (total active, reactive and apparent power, power factor) and digital input status information (up to 32 inputs).
- Phasor components can include 3 voltage and 3 current phasors, positive sequence voltage and current phasors, negative sequence voltage and current phasors, or all of them in one frame.
- Complex phasor values can be sent in a rectangular coordinates format (real and imaginary) or in polar coordinates (magnitude and angle).
- Phasor and frequency data can be represented in 32-bit IEEE floating-point format or as 16-bit scaled integer numbers. When using the integer format, the data conversion factors are provided in IEEE C37.118.2 configuration frames.
- The PMU PRO supports CFG-1, CFG-2 and CFG-3 configuration frames.
- In spontaneous UDP data transmission mode, CFG-2 or CFG-3 configuration frames can be sent spontaneously without an explicit user command. When enabled, a configuration frame is sent periodically every 30 seconds.
- 5 data streaming slots for continuous synchrophasor data streaming via unicast UDP or/and TCP connections
Plug-In Modules
Automation & Control Modules

8 Digital Input
8 optically isolated digital inputs, available as:
- 24V dry contact
- 24/48/125/250V AC/DC wet input
Programmable de-bounce time from 1 ms to 1 sec
1ms sampling rate
1pps time synchronization

4 Digital Output
4 optically isolated digital outputs, available as:
- Electro-Mechanical relay, 250V / 5A AC
- Solid-State Relay, 250V / 0.1A AC

Combo: 4 DI + 2 RO
Available per above specifications (DI: @ 24V DC only)

4 Analog Outputs
Universal (configurable) isolated analog outputs
- ±1 mA
- 0-1 mA
- 0-20 mA
- 4-20 mA
Auxiliary Power Supply Module

Auxiliary Power Supply
- 88-264V AC
- 90-290V DC

DC Auxiliary Power Supply
- 24V DC (9-36V DC)
Tech Specs
-
Logging, Recording & Programming
- Programmable controller: up to 32 control setpoints and half-cycle scan time
- OR, AND, arithmetical functions logic, extensive triggers, programmable thresholds and delays, relay control, event-driven data recording
- Event recorder for logging internal diagnostic events, power faults and operations of the logic controller and digital I/O
- 8 data recorders with programmable datasets for data logging on a periodic basis and on any internal or external trigger
- 32 digital counters for counting internal events and pulses from external sources
- 16 interval timers with programmable periods from ½ cycle to 24 hours for periodic recording and triggering timed operations
-
-
Variable Current Inputs
- 5A
- 1A
-
Voltage Measurement Inputs
- Measurement category: CAT III
- Operating range: up to 277/480V AC + 25%
-
-
I/O
- Built-in I/O
- 1 AI (±1 mA; 0-1 mA; 0-20 mA; 4-20 mA)
- 1 SSR (100mA/250V AC/DC) External power supply 24/48/125/250V DC
- 1 DI Internally wetted @ 24VDC
- 4 Relay Outputs - Electromechanical (SPST Form A)
- 5A/30 VDC
- 5A/250V AC
- 100mA/800V DC
- Combo: 4 Digital Inputs + 2 Relay Outputs
- 4 Analog Outputs
Universal (configurable) isolated analog outputs
- ±1 mA
- 0-1 mA
- 0-20 mA
- 4-20 mA
- Built-in I/O
-
Communication Interfaces
- Two 10/100Base-T IEEE 1588 Ethernet ports
- Packet forwarding / routing capabilities
- Connecting to Ethernet through one or two different network switches
- Daisy chaining multiple devices to a switch using a linear or ring network topology (daisy chaining is not available for PTP-enabled devices)
- Up to 8 simultaneous TCP connections via Modbus TCP, DNP3, IEC 60870-5-104, IEC 61850 protocols
- Up to 5 client associations, GOOSE and MSV publishers
- Up to 5 TCP or/and UDP synchrophasor data streams via C37.118.2 protocol
- Full speed USB 2.0 type C port for local configuring and monitoring the device via Modbus RTU protocol
- Modbus TCP notification client
- Expertpower Client
- RS-485 serial communication port
- 2400 - 115200 bps
- Modbus RTU, DNP3 and IEC 60870-5-101 protocols
- Using the IRIG-B time synchronization source disables the port
- Two 10/100Base-T IEEE 1588 Ethernet ports
-
Display
- High contrast 1.77” TFT color graphics display with configurable backlight
- Multi-page displays; time, instrumentation and service data
- Menu-driven setups
- Multilanguage support
-
Real-Time Clock & Synchronization
- High-accuracy real-time clock with a lithium backup battery
- Clock synchronization to a UTC time reference using an IRIG-B timecode source or an IEEE 1588 PTPv2 master clock
- Daylight saving time shift for local time indication with configurable DST start and end time
-
Power Supply
- Built-in
- 57.7-277V AC / 48-290V DC
- Additional options:
- AUX 88-264V AC / 90-290V DC
- AUX 9-36V DC
- Built-in
-
-
Enhanced Meter Security
- 3 levels Password security for protecting meter setups and accumulated data from unauthorized changes
-
Mounting
- DIN Rail mount
-
Downloads
Technical Information
- PMU PRO Phasor Measurement Unit - Installation and Operation Manual
- PMU PRO Phasor Measurement Unit - Modbus Communications Protocol
- PMU PRO Phasor Measurement Unit - DNP3 Communications Protocol
- PMU PRO Phasor Measurement Unit - IEC 60870-5-101/104 Communications Protocol
- PMU PRO Phasor Measurement Unit - IEC 61850 Communications Protocol
- PMU PRO Phasor Measurement Unit - IEEE C37.118.2 Synchrophasor Data Transfer Protocol
- PMU PRO Phasor Measurement Unit - IEC 61850 Conformance Statement (PICS, PIXIT, MICS, TICS)