DC Compatible Multifunctional three-phase Power Meter
SATEC PM130 PLUS
Description
The PM130 PLUS provides a cost-effective substitute for numerous analog meters used by industrial, commercial and utility customers for basic power metering.
Featuring versatile I/O options, communication ports and protocols, it is ideal for integration in utility substations or industrial SCADA systems.
With the addition of the unique TOU module, the EH model answers the needs of revenue metering applications. It is also suitable for utility substation automation with its support of the industry standard DNP 3.0, Modbus TCP/RTU and IEC 60870-5-101/104, as well as its I/O capabilities (using the Digital Input/Output modules).
A bright 7-segment LED display, accompanied by a LED load-bar, enables easy on-site access to power parameters and viewing of load percentage at a glance.
DC Metering
The PM130 PLUS features precise Direct Current (DC) metering using Direct Current sensors, setting it apart as a distinctive meter suitable for DC applications like renewable energy systems and data centers.
It seamlessly integrates SATEC’s features, including data logging, high accuracy, and advanced communication protocol options.
SATEC DC metering platform
- Average and Real Time values: Voltage, Current, Power, Bidirectional DC energy calculation
- Voltage range: 20-3,000V DC
- Current range: up to 3,000A DC
- Energy metering accuracy: starting 0.2%
Models
All models offer identical communication and control features
-
PM130P PLUS
Power Version -
PM130E PLUS
Energy Only -
PM130EH PLUS
Energy & Harmonic Version
Plug-In Modules
Tech Specs
-
Multifunctional 3-Phase Power Meter
- Voltage, current (including neutral current), power, energy, power factor, frequency, voltage/current unbalance and many more
- Ampere/Volt demand meter
- 25, 50, 60 and 400 Hz measurements @ 3 decimal digit values
- Sampling frequency: 128 samples per cycle
-
Harmonic Analyzer (PM130EH Plus)
- Individual voltage & current harmonic spectrum and harmonic angles up to 40th order harmonic
- Voltage and current THD, TDD and K-Factor
- Real-time “scope mode” waveform monitoring via PAS software
- Waveforms 128 samples/cycle (via comm.)
-
Billing/TOU Energy Meter
PM130E Plus & PM130EH Plus- Accuracy
- Class 0.5S per IEC 62053-22
- Class 0.2S as optional calibration
- Class 0.2 per IEC 61557-12
- Class 0.5 per ANSI C12.20
- Four-quadrant active and reactive energy polyphase static meter
- Three-phase total and per phase energy measurements; active, reactive and apparent energy counters
- Time-of-Use, 4 totalization and tariff energy/demand registers x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day
- Easy programmable tariff calendar schedule
- Automatic daily energy and maximum demand profile log for total energy and tariff registers
- Accuracy
-
-
Event And Data Recording
PM130E Plus & PM130EH Plus- Non-volatile memory for timestamped event and data recording: 48 days for 2 daily TOU records, half-hourly writing of 4 parameters and recording over 100 events during the entire period
- Event recorder for logging internal diagnostic events and setup changes
- Two data recorders; programmable data logs on a periodic basis; automatic daily energy log and maximum demand profile
-
Programmable Logical Controller
- Embedded programmable controller
- 16 control setpoints; programmable thresholds and delays
- Relay output control
- 1-cycle response time
-
-
Voltage Direct Measurement
- 0-690V AC
- 0-670V DC
- Extended range up to 1500V DC is possible via SATEC VRM
-
Current Options
- 1A or 5A inputs from CT secondary
- 40mA input designed for SATEC HACS CTs (100-3000A options)
- DC metering: current measurements using Hall Effect Sensors. meter accuracy: 0.5%. System accuracy set by implemented sensor
- RS: unique input for 5A rated HACS CT
-
Communication
- Built-in
- Standard 2-wire RS-485
- Optional interfaces (1 per device)
- ETH (10/100Base T)
- 2G/3G cellular modem
- Multipurpose RS-232/422/485
- PROFIBUS
- RF (certain regions only)
- Client - Modbus/TCP over ETH or 3G/4G
- TCP notification client for communicating events or periodic reports to remote server
- Expertpower client on subscription basis
- Communication protocols
- Modbus RTU
- SATEC ASCII
- DNP 3.0 (Level 2)
- IEC 60870-5-101 (optional)
- IEC 60870-5-104 (optional)
- Built-in
-
I/O Options
- TOD (TOU+4DI) - four digital inputs with 1-ms scan time and battery backup for real time clock; automatic recording of last five digital input change events with timestamps (see the PM130 PLUS Modbus Reference Guide)
- DIOR - 4 digital inputs and 2 relay outputs with 1-cycle update time; unlatched, latched, pulse and KYZ operation; energy pulses, selection of solid state or electromechanical relays
- 12DIOR - 12 digital inputs, 4 relay outputs (including optional ETH port or additional RS485 port)
- 4AO - four optically isolated analog outputs with an internal power supply; selection of 0-20mA, 4-20mA, 0-1mA, ±1mA, 0-3mA, ±3mA, 0-5mA and ±5mA output; 1 cycle update time
- 8DI - eight digital inputs with 1-ms scan time
-
Software Support
- SATEC’s Power Analysis Software (PAS) for comprehensive configuration and data acquisition is available for download (free)
- SATEC’s Expertpower™ web-based energy management platform (subscription)
- Any 3rd party software supporting open-protocol
-
Display
- Easy to read 3-row (2x4 digits + 1x5 digits) bright LED display
- Adjustable display brightness and update rate
- Auto-scroll option with adjustable page; autoreturn to a default page
- LED bar-graph displaying load as percentage of nominal load current (user-definable)
-
Meter Security
- Password security for protecting meter setups and accumulated data from unauthorized changes
-
Upgradeable Firmware
- Device firmware is easily upgraded through the serial or Ethernet port
-
Accuracy
- Complies with IEC62053-22, class 0.2S
- Meets ANSI C12.20-1998, class 10 0.5%
- Complies with IEC 61557-12 (PMD):
- Total Apparent Power 0.2%
- Total Active Energy 0.5/0.2%
- Total Reactive Energy 0.5%
- Frequency 0.05%
- Current 0.2%
- Neutral Current 0.2%
- Voltage 0.2%
- Power Factor 0.2%
- THDV, THDI 1%
-
-
Real-Time Clock
- Internal clock with 20-second retention time with battery backup
- Optional battery backup (TOU+4DI module)
-
Unique Design
- Pass through CT connection
- Built-in auxiliary terminal for loose CT wires.
- Dual panel mounting: 92×92mm square or 4” round cutout
-
Downloads
Marketing Materials
Technical Information
- PM130 PLUS Quick Start Manual
- PM130 PLUS Installation and Operation Manual
- PM13x External CT
- PM130 PLUS Modbus Communications Protocol
- PM130 PLUS IEC60870-5-101/104 Communications Protocol
- PM130 PLUS DNP3 Communications Protocol
- PM130 PLUS PROFIBUS DP Communications Protocol
- PM130 PLUS ASCII Communications Protocol